Logopsi

PSI Controller 3S

SWISS MADE BY RELEC SA


REAR PANEL

ControllerBackPanel

 

1. INPUT XLR symmetrical input:
1 = ground
2 = in phase signal
3 = off phase signal
(This input is mixed with the front input for fixed or special applications)

2. OUTPUT TO AMP Output of the "Controller" to the input of the amplifier.
XLR: 1 = ground
2 = signal (min 1kOhms load imp.)
3 = ground (min 1kOhms load imp.)

3. INPUT FORM AMP Input of the "Controller" from the loudspeaker output of the amplifier.
Speakon® socket : 1+ = From Amp.+
1- = From Amp.-

4. SPEAKER Speakon® socket: 1+, 1- loudspeaker output
2+, 2- control signal input.
(This output is linked with the front speaker output for fixed applications)

5. POWER SUPPLY
MAIN VOLTAGE SELECTOR 115V/230 V; 50-60 Hz; 10, VA
FUSE D=5x20, 115Vac :T80mA / 230Vac:T50mA

 


©2000 RELEC SA